r/electronics • u/Neat_Ad_6297 • 6h ago
r/electronics • u/elcoanlanka • 23h ago
Gallery I recently designed 8 channel fully isolated RS-485 based Relay controller using CH42V003
r/electronics • u/Aarombts • 9h ago
Gallery Repair Guide: SYNCO G2 Pro RX Receiver Module (Autonomous)
### 1. Original Behavior and Diagnosis
* **Symptom:** The device charged and operated normally when connected to the charger, even allowing it to be unplugged and continue working. However, the failure occurred when turning it off; it wouldn't turn back on independently unless the charger was reconnected.
* **Diagnosis Process:** Exhaustive tests were performed, ruling out various components like the power button, battery, and motherboard capacitors, ultimately finding a damaged P-type MOSFET in the power section.
### 2. Tools and Materials Needed
* Precision multimeter
* Soldering station
* Flux and isopropyl alcohol
* Precision screwdrivers
### 3. Module Disassembly
* Carefully remove the screws to open the module.
* Separate the pressure tabs.
* Carefully lift the back cover where the battery is attached, being mindful of the wiring connected to the main board.
### 4. Repair Procedure
* Locate the power circuit section where the P-type MOSFET identified in the diagnosis operates.
* Apply flux and use the soldering station to extract the defective component.
* Once the P-type MOSFET causing the power-on failure is removed, clean the area with isopropyl alcohol and proceed as needed to restore the power line.
### 5. Subsequent Tests and Reassembly
* Test the receiver's autonomous power-on without connecting an external charger.
* Correctly align the circuit board inside the casing, securing the buttons and pins.
* Close the cover, tighten the screws, and perform the final operational test.