r/firealarms 14d ago

Mod Approved CFAA warning about fraudulent emails.

13 Upvotes

Just a heads up to all CFAA registered techs. Got an email from the CFAA this morning warning that Jackie Jones, the lady who handles all things technician related at the head office had her email hacked.

"Hello All,

Please note that Jacqueline Jones' techadmin@cfaa.ca email address has been compromised. Please do not to open or click on any Links in emails received from [techadmin@cfaa.ca](mailto:techadmin@cfaa.ca) address with the subject line - Canadian Fire Alarm Association– #CFAA-AUG-2026 or any other email you may have received from this email address within the last 24 hours. 

Please rest assured that we are fully committed to resolving this situation as quickly as possible. We will send an updated email from info@cfaa.ca once this is resolved.

In the meantime, we recommend that you remain vigilant and ignore any suspicious or unexpected emails you may receive from our domain.

We sincerely apologize for any inconvenience this may cause and thank you for your understanding.

Best regards,

Jacqueline Jones and the CFAA Team"


r/firealarms 3d ago

Meme Weekly /r/FireAlarms Memes - Share your Memes!

3 Upvotes

r/firealarms 7h ago

Vent All that work for the electricians to make it look like sh**

Post image
28 Upvotes

Dont you hate it when...


r/firealarms 6h ago

Discussion SA-USB

Post image
11 Upvotes

need to know if anybody has thought about a “ case “ or some sort of protection for these ? i’m always scared im going to break it.


r/firealarms 10h ago

Vent Absurd Battery Pricing

3 Upvotes

We have a customer with a KCI master box. Technician that researched it said they need to be replaced with the specific battery from the manufacturer. MILITARY GRADE 12V8AH SLA...... Parts guy came over and said custome cost for 2 is close to 2700.

Either my parts guy screwed up his markup or that is the biggest rip off I have seen since last months super special fire wire that was 8 times the cost of the same wire that wasn't red


r/firealarms 14h ago

Discussion Fire Alarm Tech Career Planning

7 Upvotes

Hello!

I've been in the industry a decade, have a NICET FAS III (SME), NICET I&TFAS II (SME), OSHA 10, and a couple other little certs that dont mean much.

What are you doing to stay intellectually stimulated or keep your resume competitive in our market? I was planning on NFPA CFPS and/or EKU FPSET degree but I don't see people that have taken that path. I know a NICET III is, "good enough" but I want more responsibility and pay lol

Managers, what are you doing to keep people educated and engaged with learning? Are people hungry to keep moving the same way?


r/firealarms 9h ago

Technical Support Siemens Pull

Post image
2 Upvotes

I’m new to the Siemens world. I have a defective HMS-D pull station and the boss ordered a replacement XMS-D. Are those interchangeable on a Cerbus panel? Or, do we need to make sure to use the HMS-D?


r/firealarms 21h ago

Fail 3 guesses

Post image
20 Upvotes

I’ll give you 3 guesses as to why I had a short on a tamper. The first two don’t count. (Previous company install)


r/firealarms 4h ago

Technical Support Im trying to use ChatGPT to reverse engineer silent knight back door code thingy, but it needs more samples

0 Upvotes

Here's mine

Hex: 5e12802a4fd84f8808a5

Result: 1,223,344

Can you post yours?


r/firealarms 1d ago

Discussion antique gamewell gong

Thumbnail
gallery
8 Upvotes

i managed to restore this old gamewell gong, M-1007-18 does anyone have a parts diagram or know where the red circled spring goes? i got it working however i’m sure this has a purpose i can’t find yet.


r/firealarms 1d ago

Discussion Does anyone know the model of this outdoor horn?

Post image
3 Upvotes

r/firealarms 1d ago

Technical Support Sk 6820 6 sk relay problem.

1 Upvotes

Have two different buildings with sk 6820 6 sk relay cards that the same relay is stuck closed. Both are triggering a point on a Monaco reporting radio. Panels are normal and there is no change after resetting or disconnecting the card from the slc. Any ideas on what I’m missing before I pop new cards in? Thanks.


r/firealarms 1d ago

Discussion Need advice…

5 Upvotes

I need advice and feedback from experienced people in this field. I recently got hired on by a company to work in Test and Inspections. I have zero experience in this trade.

I applied to do the Fire Alarm side whether that was service or testing. The past month I have just been bounced around doing both Fire and Sprinkler. I realize they work together but I’m not learning much at all. Is this normal?

I would think doing install or service would be better to learn how the systems work and have the ability to troubleshoot things before jumping into Inspections. I’m pretty stressed, I realize it takes time to learn things but I feel like I’ve been thrown to the wolves and am not getting properly trained.

I’ve also been bounced around with different techs every day. There’s really no consistency, The company pays well but my biggest concern is I want to “learn”. I thought I would of solely been working on just the Fire Alarm side.


r/firealarms 2d ago

Proud Enthusiast Help finding tone on an ifp-2100-ecs

Enable HLS to view with audio, or disable this notification

6 Upvotes

The building next to me has a triga fire alarm system. You may not know what triga is. But in short, it’s a rebrand of Honeywell farenhyt. Anyway, I captured a video of the system going off, and I’ve heard the tone used in their voice evacuation is quite unique. I want to find that exact tone. At the start you can hear a “dee doo dee” tone. I checked the manual for it and it lists all the tones. I’m thinking it’s the high low tone. I just need help finding that audio tone because I want to use it in an upcoming project. The panel is a Triga/Farenhyt TR/IFP-2100ECS


r/firealarms 2d ago

Technical Support Farenhyt IFP-2100 contractor left with the password

4 Upvotes

Any Idea on whats the process on how to get the password back through Honeywell the panel was commissioned by a contractor and after finishing the project didn’t give the password 2 years ago now the panel have multiple faults and renovations require editing and labeling the devices?


r/firealarms 2d ago

Work In Progress Help silent knight 6808

1 Upvotes

Did a fire inspection with no walk test the next morning the panel sent in random alarms and supervisors. There was 110 devices I’m on my way to site now what can I do to fix this? This has never happened before


r/firealarms 2d ago

Discussion Where can I get ULC S524 pdf

0 Upvotes

Hello can someone please help me, I'm a broke apprentice I really need a copy to study where can I get for cheapest possible it's very expensive and out of budget


r/firealarms 2d ago

Discussion TFM11 Study Guides

0 Upvotes

Wassup good people! I was wondering if anyone in Texas has taken the FAL TFM11 I just passed the TFM12 with the help of an anon here giving me some study guides and tips. If anyone has any tips, company study guides, or just things you found online you used that were extremely helpful for the test that would be amazing! Appreciate y’all!


r/firealarms 3d ago

Discussion Test Question

0 Upvotes

I had a test question that I can’t remember verbatim.

Effectively it was asking what was the subnet it static ip when having a fire alarm connected up to a router.

It was like:

255.0.0.0
255.255.0.0
255.255.255.0
255.255.255.255

192.168.0.0
192.168.1.0
192.168.0.1
192.168.1.1

Other part was if it’s attaching a releasing panel to a buildings router what is the router address to be offered to IT?


r/firealarms 4d ago

Discussion Cool find

Thumbnail
gallery
42 Upvotes

This finally bit the dust and got to replace it last thursday in Northern saskatchewan, building still has one of these bells holding on


r/firealarms 4d ago

Discussion Speaker Circuit and SLC in the Same Conduit

15 Upvotes

This is regarding a school modernization project with voice evacuation. Everything will be in surface mount EMT or Wiremold.

Spec is for Unshielded Twisted Pair Speaker and Unshielded Twisted Pair SLC in the same conduit (thousands of feet of shared conduit). Spoke with Potter tech support, and they said that unshielded twisted pair for the speaker circuits is okay in the same conduit as the SLC and that the voice cards/amps do not even have a terminal for a drain wire. I am a little suspicious and it seems a little concerning to have thousands of feet of Speaker and SLC ran in parallel and hoping no interference occurs. The IPA-4000V engineering specifications clearly state the speaker and V-link circuits can not share the same conduits as the signaling line circuit.

What are your guys' thoughts on this. Have you guys come across issues with speaker and SLC in the same conduit? According the engineering specs, seems like the architect needs to add a separate conduit run for the speakers.


r/firealarms 4d ago

Work In Progress Nicet 1

5 Upvotes

I'm about to take my nicet 1 exam on Monday. Ive been in the industry for about two years but had a setback due to some medical complications blah blah blah so I'm a little behind. Does anyone have any tips or pointers for this test?


r/firealarms 4d ago

Technical Support Powerstrike and P2Wled h/s temp 4 causing overload.

2 Upvotes

I just fninshed wiring up a new powerstrike 6 amp PS connected to a System Sensor P2WLED. PS set to master temp 4 coding and H/S to temp3/Temp4 Low. No sync signal from panel (triggered by control module). When the PS gets triggered the H/S doesn't go off and the PS just flashes that output as overload. If I change output to constant it works but I get Temp 3. What the heck am I doing wrong, I can't seem to find anything on this anywhere. I can't use the FACU NAC to trigger as it is not only in use but the customer specs require that the CO H/S be fired from the power supply.

I know I am missing something stupid here but it is Friday and my brain has mushed.


r/firealarms 4d ago

Discussion Fire alarm myths

23 Upvotes

What are the best fire alarm myths you’ve encountered? My favorite is the purple dye packs being in the pull stations so you can identify who pulled it. I remember hearing that back in middle school 30+ years ago.


r/firealarms 4d ago

Discussion Weekly /r/FireAlarms Bragging - tell us about your new gears, troubleshooting technique, swag!

3 Upvotes

Time to brag! New gear? New crew? On vacation? Personnal troubleshooting techniques? Come'on makes us jealous of you!